Consulting email:

Sertech001@gmail.com

8705 Flanged Magnetic Flowmeter Sensor

Rosemount 8705 Flanged Magnetic Flow Meter Sensors provide long-lasting, reliable performance in even the most challenging applications. An all-welded construction provides a hermetic seal that protec

62.2K
0
0
0

Rosemount 8705 Flanged Magnetic Flow Meter Sensors provide long-lasting, reliable performance in even the most challenging applications. An all-welded construction provides a hermetic seal that protects against moisture and other contaminants. The sealed housing ensures maximum sensor reliability by protecting all internal components and wiring from even the most aggressive environments. A removable and replaceable terminal block enables easy repair in the field without the need to replace the entire meter.

Accuracy

Up to 0.15% of volumetric flow rate accuracy over 13:1 flow turndowns, 0.25% over 40:1 flow turndown

Line Sizes

½-36 inch (15-900 mm)

Liner Materials

PTFE, ETFE, PFA, Polyurethane, Neoprene, Linatex Natural Rubber

Electrode Materials

316L Stainless Steel, Nickel Alloy, Platinum, Tantalum, Titanium

Flange Ratings

ASME B16.5 Class 150-2500DIN PN 10-40AS 2129 Table D and EAWWA C207 Table 3 Class D (30-36 inch only)

Submergence Protection

IP68 (Recommended with sealed cable glands)

Interchangeability

Compatible with all 8700 Series transmitters
Compatible with legacy transmitters: 8712D, 8712C, 8732C, 8742C


Carton or wooden box